How to keep the DC INVERTER CONDENSING UNIT effect stable

DC INVERTER CONDENSING UNIT

DC INVERTER CONDENSING UNIT

DC INVERTER CONDENSING UNIT

DC

Today, we will introduce 5 processes to you, so that the cooling effect of DC INVERTER CONDENSING UNIT can remain stable all year round. Let us take a look at the details.

DC INVERTER CONDENSING UNIT

1. Check the DC INVERTER CONDENSING UNIT compressor regularly
The compressor is the "heart" of the air-cooled condensing unit. Its quality directly affects the stability of the air-cooled condensing unit. If the compressor failure is repaired, the cost is relatively high, especially the price of the compressor. Therefore, if you hear the abnormal sound of the compressor or other conditions, you must contact the DC INVERTER CONDENSING UNIT factory to find a professional engineer to check, find out the reason and repair it.

2. Regularly clean the DC INVERTER CONDENSING UNIT condenser and evaporator
The condenser/evaporator is the second most important component of the DC INVERTER CONDENSING UNIT and should be cleaned every six months. The cooling water of the water-cooled condenser is an open circulation loop, and the tap water used is circulated through the cooling water tower, which is easy to decompose and accumulate impurities on the water pipe to form scale, which affects the heat transfer. If the scale is too thick, the flow section of the cooling water will also be reduced, the water volume will be reduced, and the condensing pressure will increase. Therefore, when the quality of the tap water used is poor, it should be cleaned at least once a year to remove the scale in the pipe and perform water treatment operations on the tap water.

3. Regularly check the chiller unit through the safety valve

The condenser and evaporator of DC INVERTER CONDENSING UNIT belong to their own pressure and container. According to relevant regulations, a safety valve should be installed on the high-pressure side of DC INVERTER CONDENSING UNIT, that is, the condenser body. Once the crew is in an abnormal work In the living environment, the safety valve can complete the active pressure relief to prevent the damage to our human health caused by high pressure.

4. Regular replacement of DC INVERTER CONDENSING UNIT using lubricating oil

After the DC INVERTER CONDENSING UNIT is used for a long time, the oil quality of the lubricating oil will deteriorate, and the impurities and moisture in the oil will increase, so you should check the oil quality regularly. Once a problem is found, it should be replaced in time, and the brand of lubricating oil to be replaced is subject to the original manufacturer.

5. Regularly replace the DC INVERTER CONDENSING UNIT boring filter
The filter drier is an important component to ensure the normal development cycle of the refrigerant. Because water and refrigerant are immiscible with each other, if a system contains water, it will greatly affect the operation and management efficiency of DC INVERTER CONDENSING UNIT, so we insist that it is very important to control drying within the information system company. Must be replaced regularly.
 