Hello, welcome to www.tianyicool.cn!

language
中文
英文
TianyiCOOL
NEWS

The working principle and structure of common HORIZONTAL TYPE CONDENSING UNIT in cold storage equipment

HORIZONTAL TYPE CONDENSING UNIT

HORIZONTAL TYPE CONDENSING UNIT

HORIZONTAL TYPE CONDENSING UNIT

HORIZONTAL

HORIZONTAL TYPE CONDENSING UNIT is one of the four indispensable parts of the refrigeration system in the cold storage. The function of the condenser is to discharge the heat from the high temperature and high pressure superheated refrigerant vapor generated by the compressor to the cooling medium (water or air). , which cools and condenses superheated steam into liquid.

HORIZONTAL TYPE CONDENSING UNIT

HORIZONTAL TYPE CONDENSING UNIT is one of the important equipments in the refrigeration system. It is the exothermic surface of the condenser, which transfers the heat of the superheated vapor of the refrigerant to the surrounding air or water, and is cooled into saturated vapor by itself, and further cooled as The high-pressure liquid is circulated in the system. The working principle and structure of common condensers are described below.

1) The air condenser is a common HORIZONTAL TYPE CONDENSING UNIT specially matched with small and medium-sized compressors such as semi-hermetic and fully-closed. The air condenser series is a radiator specially designed for semi-hermetic and fully-hermetic compressors; there are four types of production: FN type, FNC type, FNV type and FNS type; FN type, FNC type , FNS type adopts side outlet type, FNV type adopts top outlet type.

2) HORIZONTAL TYPE CONDENSING UNIT The refrigerant vapor condenses on the outer surface of the tube, and the cooling water flows in the tube under the action of the pump. The refrigerant vapor enters from the upper intake pipe, condenses into liquid and flows into the liquid reservoir from the liquid outlet pipe at the lower part of the cylinder. The two ends of the cylinder of the condenser are sealed with end caps, and the water separators are used in the end caps to realize the multi-tube flow of cooling water. The number of tube bundles of the condenser is an even number, so that the inlet and outlet of cooling water can be set on the same end cover, and the lower inlet and upper outlet can be arranged.
 